Flange Mounted Liquid Level Transmitter

Flange Mounted Liquid Level Transmitter

flange mounted liquid level transmitter Introduction With liquid level Transmitter, you’ll gain more control over your plant. You’ll be able to reduce product variation and complexity as well as your total cost of ownership by leveraging one device across a number of pressure, level and flow...
Chat Now

Product Details

flange mounted liquid level transmitter


Introduction

With liquid level Transmitter, you’ll gain more control over your plant. You’ll be able to reduce

product variation and complexity as well as your total cost of ownership by leveraging one device
across a number of pressure, level and flow applications. You’ll have access to information you can

use to diagnose, correct and even prevent issues.


Features

1. Process Fluid: Liquid, Gas, Vapor

2. Applicat ion: Differential Pressure, Gauge Pressure,Absolute Pressure

3. Working Temperature: -25 to +95C

4. Current Output: 4 - 20 mA 2 wires Har t Protocol

5. Power Supply: 24VDC

6. Ambient Temperature: -25 to +240C

7. Process connections: 1/4 - 18 NPT or 1/2 - 14 NPT

8. Electrical Connections: 1/2”NPT or M20*1.5

9. Enclosure:IP65

10.Intrinsically Safe: ia II C T6

11.Explosion proof: d II B T5


a0a633eac02e00ca9a44ef155732.jpg

20150722143935_56645.jpg

image_11064.jpg



pressure media

Viscous liquid compatible with 316LSS

measuring ranges

mH2O

0~1,…0~50

pressure type

Gauge pressure

overload pressure

%FS

300

excitation voltage

Vdc

+12~+36(calibration value:+24)

output signal

4~20 (1V~5V) 2-wires;0~10 (0V~5V) 3-wires

accuracy

%FSO

0.1

0.25

0.5

long-term stability

%FSO /year

0.1

0.2

0.3

zero offset

%FSO/4h

≤0.1

≤0.25

≤0.5

temp.coefficient of ZERO

%FSO /°C

≤0.01

≤0.03

≤0.05

temp.coefficient of SPEN

%FSO /°C

≤0.01

≤0.03

≤0.05

operating temp. range

°C

-20~+85

compensated temp. range

°C

0~+80

response time

ms

≤1

pressure interface

flange

DN20……DN50

electrical interface

1 meter length cable, PVC

explosion

Exia II CT6

environment protection

IP 67


Specification

Specifications

measuring media

liquids compatible with wetted parts

measuring ranges

mH2O

0~0.6,0~1,0~2,0~5,0~10,0~20,0~50,0~100,0~200

overload pressure

%FS

200 (range≤2 m H2O), 300 (range<2 m H2O)

supply voltage

Vdc

24 (recommended, 12,, 36

output signal

current

4~20 mA (standard), option:4~20 mA with HART, 0~5V or 0~10 V

accuracy

%FSO

± 0.5

long-term stability

%FSO/year

< ± 0.15

Load resistance

Ω

250~1150

insulation resistance

>500 @ 100 Vdc

storage temperature range

-40~+85

media temperature range

40 ~+125

operating temperature range

20 ~+80

compensated temperature ranges

0~+70

temperature coefficient of ZERO

%FSO/

± 0.01

temperature coefficient of SPAN

%FSO/

± 0.01

process connection

flange type

flange type 1, type2,type3,type4; or customer requested

materials

316 SS (standard), 316L SS, Hastelloy-C, Monel

electrical connection

internal thread

M20 × 1.5 (standard), 1/2 NPT

display

4 1/2 digits LCD display(standard), no display

pressure membrane material

316L SS

housing material

316 SS

environment protection

IP rating

IP 65