Features
●Rosemount Coplanar platform enables integration of primary elements, manifolds, and remote seal solutionsn
●Best in Class performance with up to 0.05% high accuracy optionn
●IEC 62591 (WirelessHART®) Protocol enables cost effective installationsn
●Local Operator Interface (LOI) offers easy to use configuration capabilities at the transmittern
●Protocols available include HART® 4–20 mA, FOUNDATION™ Fieldbus, PROFIBUS® PA, HART 1–5 Vdc Low Power
●SIL2/3 safety certification to IEC 61508 is available with the full 4–20 mA HART offering to simplify compliance
Specifications
Operating Pressure |
Max. 300 psi (20,68 bar) |
Process Temperature |
Maximum 401°F (205°C), Minimum -157°F (-105°C) |
Communication Protocol |
4-20 mA HART, WirelessHART, FOUNDATION Fieldbus, PROFIBUS, 1-5 V Low Power HART |
Seal System Type |
Direct Mount, Tuned-System |
Transmitter Connection |
Welded-Repairable |
Process Connection |
Flanged: ANSI/ASME, EN/DIN, JIS |
Process Wetted Material |
316L SST, Alloy C-276, Tantalum |
Diagnostics |
Basic Diagnostics |
Certifications/Approvals |
SIL 2/3 certified to IEC 61508, NACE |
Operating Pressure |
Maxi. 300 psi (20,68 bar) |