Introduction
Approved for Division 2, Zone 2 hazardous and corrosive atmospheres, and with optional Zone 0 intrinsic safety compliance, the 117 Series can be used to measure vacuum, pressure, differential pressure, or temperature in a variety of applications.
The rugged, one piece enclosure features a slanted cover for wiring accessibility to the enclosed terminal block that is wired to either a SPDT or DPDT hermetically sealed microswitch.
All welded,stainless steel pressure connections and sensors provide superior corrosion resistance NACE compliant and fire-safe protection within the harshest environments.
The 117 Series is an ideal choice for the most demanding applications; typically steel and aluminum mills, chemical and petrochemical plants, pulp and paper mills, wastewater treatment plants, midstream and downstream oil & gas,and pharmaceutical plants.
Specifications
Storage temperature:-65° to 160°F (-54 to 71°C)
Ambient temperature limits: -40° to 160°F (-40° to 71°C); except models 520-525, 540-548, 700-706: 0 to 160°F (-18 to 71°C); set point typically shifts less than 1% of range for a 50°F (28°C) ambient temperature change
Set point repeatability Temperature models: 1% of adjustable range
Pressure models 171-174, 218, 358-376, 520-535, 540-543 and 700-7061% of adjustable range; models 183-194, 544-548, 483-494, 565-5671.5%of adjustable Internal set point lock on all pressure models
Shock: Set point repeats after 15 G, 10 millisecond duration
Vibration: Set point repeats after 2.5 G, 5-500 Hz
Enclosure: Diecast aluminum, epoxy powder coated, gasketed; captive cover screws; anodized aluminum nameplate
Enclosure classification: Enclosure Type 4X
Switch output: One SPDT hermetically sealed snap action switch; switch may be wired normally open or normally closed; DPDT (option 1190/1195)
Electrical rating: 11 A 125/250 VAC resistive; 5 A @ 28 VDC; 1 A @ 48 VDC; 1/2 A @ 125 VDC; switch contacts gold flashed
Weight: 1.5-6.5 lbs. Varies with model
Electrical connection: 1/2” NPT (female); two 7/8” diameter knockouts
Pressure connection: Models 218, 358-376, 700-706: 1/4” NPT (female); models 171-194, 483-494, 520-535: 1/2” NPT (female); models 565-567: 1.5” flush mount connection (mates with Tri-Clamp fitting systems), models 540-548: 1/8” NPT (female)
Temperature assembly: Bulb and capillary: 6 feet; 304 stainless steel
Immersion stem: nickel-plated brass (standard); optional 316L stainless steel
Fill: Non-toxic oil filled
Temperature deadband: Typically 4% of range under laboratory conditions (70°F ambient circulating bath at rate of 1/2°F per minute change)
Reference Scale Pressure: High-Low
Features