yokogawa ejx110A pressure transmitter
Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAINor HART communications. Other key features include quick response, remote set-up using communications,diagnostics and optional status output for pressure high/low alarm. The multi-sensing technology provides
the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available. All EJX series models in their standard confi guration, with the
exception of the Fieldbus and PROFIBUS types, are certifi ed by TÜV as complying with SIL 2 for safety requirement.
Specifications | EJX110A Differential Pressure Transmitter | ||||
L Capsule | M Capsule | H Capsule | V Capsule | ||
Range | -10 to 10 kPa | -100 to 100 kPa | -500 to 500 kPa | -5 to 14 MPa | |
Span | 0.1 to 10 kPa | 0.5 to 100 kPa | 2.5 to 500 kPa | 0.07 to 14 MPa | |
Accuracy | ±0.04% | ±0.04% | ±0.04% | ±0.04% | |
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | ||||
Certificates | FM, CENELEC ATEX, CSA, IECEx | ||||
Output | 4 to 20 mA DC or FOUNDATION™ fieldbus, 2-wire system with digital communication | ||||
Supply voltage | BRAIN and HART:10.5 to 42 V DC | ||||
Ambient temperature | -40 to 85 deg C (-40 to 185 deg F) (general use type) | ||||
Process temperature | -40 to 120 deg C (-40 to 248 deg F) (general use type) | ||||
Maximum working pressure | 16 MPa | 25 MPa | |||
Mounting | 2-inch pipe mounting | ||||
Wetted parts material | Capsule | 316L SST(Diaphragm material is Hastelloy C-276), | |||
Cover flange | ASTM CF-8M,Hastelloy C-276,Monel | ||||
Housing | Cast aluminum alloy or ASTM CF-8M stainless steel (optional) |